Excellent tip from Mariano Gomez and Frank Hamelly -
How to automatically send all posting reports to screen in Microsoft Dynamics GP
This is something that has pained me for a long time! Mariano has given the following script on his blog which forces all reports to screen.
UPDATE SY02200 SET ASECTMNT = 0, PRTOPRNT = 0, PRTOSCNT = 1, PRTOFLNT = 0
GO
1 comment:
Jiv,
Just one clarification: it's all posting journal reports.
MG.-
Mariano Gomez, MIS, MVP, PMP
Maximum Global Business, LLC
http://www.maximumglobalbusiness.com